**1. What is another name for the exclusion zone?**

- Cold zone
- Warm zone
- Hot zone
- Safe zone

**Answer: Hot zone.** The exclusion zone is the hot zone where contamination is or could be present.

**2. The decontamination line is set up in order from:**

- Cleanest to dirtiest
- Dirtiest to cleanest
- Any order
- Alphabetical by station

**Answer: Dirtiest to cleanest.** Decon moves workers from the most contaminated station to the least contaminated.

**3. When must a written decon procedure be in place?**

- Before anyone enters the site
- After the first exposure
- At the end of the project
- Only for Level A work

**Answer: Before anyone enters the site.** 1910.120(k)(1) requires the procedure to be developed and communicated before entry.

**4. What is usually the first station on a decon line?**

- Inner glove removal
- Segregated equipment drop
- Facepiece removal
- Field shower

**Answer: Segregated equipment drop.** Workers first drop tools and instruments on plastic or in containers before washing.

**5. What should you do with protective clothing that can't be decontaminated?**

- Take it home to wash
- Reuse it the next day
- Dispose of it properly
- Store it in the support zone

**Answer: Dispose of it properly.** PPE that can't be decontaminated must be disposed of; contaminated clothing never goes home.

**6. Which is NOT a required element of the site control program?**

- Site map
- Work zones
- Buddy system
- Employee vacation schedule

**Answer: Employee vacation schedule.** Site control needs a site map, work zones, buddy system, communications, SOPs and nearest medical assistance.

**7. If a seriously injured worker is contaminated, you should:**

- Delay medical care until full decon is finished
- Give life-saving care first and do gross decon only if it doesn't delay care
- Leave the worker in the hot zone
- Skip telling medical staff about the chemical

**Answer: Give life-saving care first and do gross decon only if it doesn't delay care.** Life-saving care comes first. Do quick gross decon if possible, and tell medical staff the contaminant.

**8. Workers enter and leave the exclusion zone through:**

- Any point along the hot line
- Access control points
- The support zone fence
- The command post

**Answer: Access control points.** Access control points control entry and exit and route workers through decon.

**9. Why are eating, drinking and smoking banned in the exclusion zone?**

- To save time
- To prevent ingestion of contaminants
- Because of noise
- It isn't banned

**Answer: To prevent ingestion of contaminants.** Hand-to-mouth contact is a key ingestion route.

**10. How can you check whether decon worked?**

- Wipe sampling or testing the final rinse
- Asking the worker
- Waiting a week
- It can't be checked

**Answer: Wipe sampling or testing the final rinse.** Visual inspection, wipe samples and rinse-solution testing show whether decon removed contaminants.

## More free HAZWOPER quizzes

- [HAZWOPER 40 Hour Practice Test](https://www.hazwoperosha.com/quizzes/hazwoper-40-hour-practice-test/) · Free quiz · 15 questions - Free HAZWOPER 40 hour practice test with answers and explanations. 15 questions on OSHA 1910.120 training levels, PPE,...
- [HAZWOPER 8 Hour Refresher Practice Quiz](https://www.hazwoperosha.com/quizzes/hazwoper-8-hour-refresher-practice-quiz/) · Free quiz · 10 questions - Free HAZWOPER 8 hour refresher practice quiz with answers. Review refresher deadlines, medical surveillance, the HASP,...
- [HAZWOPER PPE Levels Quiz (Levels A, B, C and D)](https://www.hazwoperosha.com/quizzes/ppe-levels-quiz/) · Free quiz · 10 questions - Free quiz on HAZWOPER PPE levels A, B, C and D with answers. Test what each level includes, when to use it, respirator...
- [Air Monitoring and Gas Detection Quiz](https://www.hazwoperosha.com/quizzes/air-monitoring-quiz/) · Free quiz · 10 questions - Free air monitoring quiz with answers: oxygen limits, LEL action levels, PIDs, FIDs, bump tests, vapor density and...
- [HAZWOPER First Responder Awareness Level Quiz](https://www.hazwoperosha.com/quizzes/first-responder-awareness-quiz/) · Free quiz · 10 questions - Free HAZWOPER first responder awareness level quiz with answers: (q)(6) responder levels, the DOT Emergency Response...
- [RCRA Hazardous Waste Generator Quiz](https://www.hazwoperosha.com/quizzes/rcra-hazardous-waste-quiz/) · Free quiz · 10 questions - Free RCRA hazardous waste quiz with answers: generator categories, accumulation limits, satellite accumulation,...

---

Page: https://www.hazwoperosha.com/quizzes/decontamination-and-site-control-quiz/
HazwoperOSHA.com: [Home](https://www.hazwoperosha.com/) · [Courses](https://www.hazwoperosha.com/#courses) · [About](https://www.hazwoperosha.com/about/) · [Contact](https://www.hazwoperosha.com/contact/) · [Privacy](https://www.hazwoperosha.com/privacy/) · [llms.txt](https://www.hazwoperosha.com/llms.txt) · [Sitemap](https://www.hazwoperosha.com/sitemap.xml)
Questions: +1-866-429-6742 · sales@hazwoper-osha.com